{"product_id":"flagro-fvo-1100tr-800-000-btu-indirect-fired-heater-trailer-oil-with-air-recirculation-capabilities","title":"Flagro FVO-1100TR 800,000 BTU Indirect Fired Heater Trailer - Oil With Air Recirculation Capabilities","description":"\u003cdiv id=\"HEADING_PARA-O1OJU36tcr\"\u003e\n\u003cdiv class=\"page_crafter_heading_para_container-O1OJU36tcr   page-crafter-div-container\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"HEADING_PARA-1muejEl3ZO\"\u003e\n\u003cdiv class=\"page_crafter_heading_para_container-1muejEl3ZO   page-crafter-div-container\"\u003e\n\u003cdiv class=\"page_crafter_para-1muejEl3ZO     page-crafter-div-container\"\u003e\n\u003cdiv class=\"page-crafter-pdf-list-container\"\u003e\n\u003cdiv class=\"page-crafter-pdf-list-item\"\u003e\n\u003ch2\u003eFlagro FVO-1100TR: 800,000 BTU Indirect Fired Heater Trailer – Oil with Air Recirculation\u003c\/h2\u003e\n\u003cp class=\"whitespace-pre-wrap break-words\"\u003eThe Flagro FVO-1100TR is a heavy-duty trailer-mounted indirect-fired oil heater delivering an impressive 800,000 BTU of combined heating power through dual FVO-400RC units with air recirculating inlets. Engineered for maximum mobile heating in large industrial and commercial projects, this system features 16-gauge 304 stainless steel heat exchangers for exceptional durability and corrosion resistance in demanding environments. The unit offers flexible heating distribution with multiple duct configurations including 4 x 12-inch or 2 x 16-inch outlets and 2 x 16-inch inlets, delivering up to 4,000 CFM of airflow for comprehensive coverage. Mounted on a robust solid steel welded channel frame with dual 3,500 lbs axles and four 15-inch rims and tires, the trailer provides reliable mobility across challenging terrains. Safety features include electric emergency brakes, lights, and safety chains for compliant transport. The system comes complete with a TC-approved 300-gallon fuel tank providing approximately 44 hours of runtime, and a reliable Kubota or Yanmar generator for continuous operation in remote or off-grid locations. Perfect for construction sites, industrial facilities, large events, and temporary heating applications where high-capacity, mobile heating is essential.\u003c\/p\u003e\n\u003cdiv id=\"SPACER-e0YFjYWziu\"\u003e\n\u003cdiv style=\"height: 20px;\" class=\"page-crafter-block\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"PDF_LIST-dB2yjzDo48\"\u003e\n\u003cdiv class=\"page-crafter-div-container\"\u003e\n\u003ch3 class=\"page-crafter-h3 page_crafter_pdf_list_heading-dB2yjzDo48\"\u003eFlagro FVO-1100TR Indirect Fired Heater Trailer Resources\u003c\/h3\u003e\n\u003cdiv class=\"page-crafter-pdf-list-container\"\u003e\n\u003cdiv class=\"page-crafter-pdf-list-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/FVO-1100TR-Operating-Instuctions-Manual-English.pdf?v=1759312399\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/FVO-1100TR-Operating-Instuctions-Manual-English.png?v=1759312497\" width=\"40\"\u003e \u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/FVO-1100TR-Operating-Instuctions-Manual-English.pdf?v=1759312399\" target=\"_blank\"\u003e FVO-1100TR Operating Instructions Manual \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page-crafter-pdf-list-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/OIL-FIRED-BURNER-PARTS-DIAGRAM.pdf?v=1759314334\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/OIL-FIRED-BURNER-PARTS-DIAGRAM.png?v=1759314360\" width=\"40\"\u003e \u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/OIL-FIRED-BURNER-PARTS-DIAGRAM.pdf?v=1759314334\" target=\"_blank\"\u003e Burner Diagram \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page-crafter-pdf-list-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/Parts-Catalogue.pdf?v=1759312396\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/Parts-Catalogue.png?v=1759312496\" width=\"40\"\u003e \u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/Parts-Catalogue.pdf?v=1759312396\" target=\"_blank\"\u003e Parts Catalogue \u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"page-crafter-pdf-list-item\"\u003e\n\u003cdiv\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/Wiring-Diagram-FVO-1000TR.pdf?v=1759312395\" target=\"_blank\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/Wiring-Diagram-FVO-1000TR.png?v=1759312496\" width=\"40\"\u003e \u003c\/a\u003e\u003c\/div\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0696\/7174\/7813\/files\/Wiring-Diagram-FVO-1000TR.pdf?v=1759312395\" target=\"_blank\"\u003e Wiring Diagram - FVO -1000TR\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch4\u003eBest For Applications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eLarge Construction Sites\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– High-capacity, mobile heating for massive outdoor or indoor job sites requiring powerful, continuous warmth\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIndustrial Facilities\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Maintains consistent heat across expansive industrial spaces, supporting operational efficiency and worker comfort\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEvent \u0026amp; Temporary Heating\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Ideal for large-scale events or temporary setups requiring powerful, reliable mobile heat solutions\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRemote Maintenance \u0026amp; Repair Operations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Keeps machinery, tools, and personnel functional in cold or remote locations without grid access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003e800,000 BTU Combined Heat Output\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Dual FVO-400RC heaters deliver massive heating capacity for large-scale applications\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAir Recirculation Capability\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Enhances energy efficiency and optimizes heat distribution across expansive spaces\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e16-Gauge 304 Stainless Steel Heat Exchangers\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Durable and corrosion-resistant construction for heavy-duty industrial use\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003e4,000 CFM Maximum Airflow\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Powerful air circulation ensures rapid, even heat distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eFlexible Ducting Options\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Multiple configurations with 4 x 12-inch or 2 x 16-inch outlets and 2 x 16-inch inlets for precise heating distribution\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHeavy-Duty Trailer Frame\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Solid steel welded channel construction for long-lasting durability\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDual Axle Design\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Two 3,500 lbs axles with four 15-inch rims and tires provide reliable mobility on challenging terrains\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectric Emergency Brakes\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Enhanced safety features with lights and safety chains for compliant, secure transport\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eTC-Approved 300-Gallon Fuel Tank\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Extended operation capacity providing approximately 44 hours of runtime, minimizing refueling downtime\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eKubota or Yanmar Generator\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Reliable on-board power source for continuous heater operation in remote or off-grid locations\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eDirect Spark Ignition\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Reliable starting system for consistent operation\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCSA \u0026amp; ESA Approved\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e– Meets stringent safety and performance standards\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003chr\u003e\n\u003cp class=\"whitespace-pre-wrap break-words\"\u003e\u003cstrong\u003eContact Us:\u003c\/strong\u003e\u003cbr\u003e\u003ca href=\"mailto:info@topcleaningequipment.com\" target=\"_blank\"\u003einfo@topcleaningequipment.com\u003c\/a\u003e\u003cbr\u003eCall Us: (844) 777-0683\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"SPACER-vacVDSazgU\"\u003e\n\u003cdiv class=\"page-crafter-block\" style=\"height: 20px;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"HEADING-CwiKgX6wYx\"\u003e\n\u003ch4 class=\"page-crafter-h3 page_crafter_heading-CwiKgX6wYx\"\u003eFVO-1100TR Specs\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"TABLE-kNqd5ar3Ml\"\u003e\n\u003cdiv class=\"page-crafter-simple-table-container page-crafter-div-container\"\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCFM (max)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192 × 88.8 × 84 in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeating Capacity \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x 390,000 BTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Capacity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e300 Gallons\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFuel Capacity\/Run Time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC APPROVED 300 US GAL\/ 44 HRS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGenerator\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eTC APPROVED 300 US GAL\/ 44 HRS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEngine\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYanmar or Kubota\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHeat Exchanger \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e16 Gauge 304 Stainless Steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIgnition\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect Spark\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Outlet \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 x 12` Dia. or 2 x 16` Dia.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eAir Inlet \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x 16”Dia.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eApprovals\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCSA \u0026amp; ESA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlet Ducting - 12”\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFV-HD12 – 12” x 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOutlet Ducting - 16”\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFV-HDG16 – 16” x 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eInlet Ducting - 16”\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFV-HDV16 – 16” x 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNozzle Size\/ Pump Pressure\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2.00 x 60B\/ 170PSI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4300 LBS.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv id=\"SPACER-e0YFjYWziu\"\u003e\u003c\/div\u003e\n\u003cdiv id=\"PDF_LIST-dB2yjzDo48\"\u003e\n\u003cdiv class=\"page-crafter-div-container\"\u003e\n\u003cdiv class=\"page-crafter-pdf-list-container\"\u003e\n\u003cdiv class=\"page-crafter-pdf-list-item\"\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e.page_crafter_heading_para_container-O1OJU36tcr  { text-align: null;     }  .page_crafter_heading-O1OJU36tcr { color: #000;  text-align: null;  font-size: null;    color: #000 !important; }  .page_crafter_para-O1OJU36tcr  { color: #000;  font-size: ;  text-align: null;    color: #000 !important; }  #HEADING_PARA-O1OJU36tcr {\n    margin-bottom: 10px;  \n  }  #SPACER-6R4g8zH5nf {\n    margin-bottom: 10px;  \n  } .page_crafter_heading_para_container-1muejEl3ZO  { text-align: null;     }  .page_crafter_heading-1muejEl3ZO { color: #000;  text-align: null;  font-size: null;    color: #000 !important; }  .page_crafter_para-1muejEl3ZO  { color: #000;  font-size: ;  text-align: null;    color: #000 !important; }  #HEADING_PARA-1muejEl3ZO {\n    margin-bottom: 10px;  \n  }  #SPACER-vacVDSazgU {\n    margin-bottom: 10px;  \n  } .page_crafter_heading-CwiKgX6wYx { color: #000;  text-align: left;  font-size: null;    color: #000 !important; }  #HEADING-CwiKgX6wYx {\n    margin-bottom: 10px;  \n  }  #TABLE-kNqd5ar3Ml {\n    margin-bottom: 10px;  \n  }  #SPACER-e0YFjYWziu {\n    margin-bottom: 10px;  \n  } .page_crafter_pdf_list_heading-dB2yjzDo48 { color: #000;  text-align: left;  font-size: null;    color: #000 !important; }   #PDF_LIST-dB2yjzDo48 {\n    margin-bottom: 10px;  \n  }  #TABLE-yGrq9MmT0q {\n    margin-bottom: 10px;  \n  }\n  \n  @media (max-width: 798px) {\n       #HEADING_PARA-O1OJU36tcr {\n    \n  }  #SPACER-6R4g8zH5nf {\n    \n  }    #HEADING_PARA-1muejEl3ZO {\n    \n  }  #SPACER-vacVDSazgU {\n    \n  }  #HEADING-CwiKgX6wYx {\n    \n  }  #TABLE-kNqd5ar3Ml {\n    \n  }  #SPACER-e0YFjYWziu {\n    \n  }   #PDF_LIST-dB2yjzDo48 {\n    \n  }  #TABLE-yGrq9MmT0q {\n    \n  }\n  }\n  \u003c\/style\u003e","brand":"Flagro","offers":[{"title":"Default Title","offer_id":47464891449518,"sku":"FVO-1100TR","price":50976.48,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0697\/4056\/0558\/files\/Flagro-FVO-1100TR-800000-BTU-Indirect-Fired-Oil-Heater-Trailer.png?v=1770325783","url":"https:\/\/www.topcleaningequipment.com\/products\/flagro-fvo-1100tr-800-000-btu-indirect-fired-heater-trailer-oil-with-air-recirculation-capabilities","provider":"Top Cleaning Equipment","version":"1.0","type":"link"}